Architect and Engineer Specifications: xOut 12.
The device shall provide twelve analog line outputs. Levels and phantom power shall be controllable via DSP modules in software. Audio connections shall be accessed via rear panel 3.81 mm terminal block connectors.
Network audio expansion shall be provided by the Dante protocol. Primary and Secondary Dante network audio connections shall be provided for redundant network implementation. Connectors shall be gigabit RJ45 utilizing CAT6 cable.
A designer software application shall be provided that operates on a Windows computer, with network interface installed, running Windows® XP or higher operating system. Computer connection for configuration shall be via a hosting DSP unit’s rear panel Ethernet connector that communicates with the device via Dante.
The front panel shall include output signal level indicators as well as indicators for POWER and DANTE (PRIMARY and SECONDARY).
Audio conversion shall be 24-bit, 48 kHz and the dynamic range shall not be lower than 118 dB, A-weighted with a maximum output level of +24 dBu.
The device shall have an IEC power input socket for 120-240 VAC. The devices shall meet UL/CSA and CE safety requirements and comply with CE and FCC Part 15 emissions limits.
The device shall be RoHS compliant. The chassis shall be constructed of cold rolled steel and moulded plastic, and mount into a standard 19” 1U EIA rack. The device shall be Symetrix xOut12.